SCAS958 November   2023 SN74AC541

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
    7. 5.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
    4. 7.4 Feature Description
      1. 7.4.1 Balanced CMOS 3-State Outputs
      2. 7.4.2 Standard CMOS Inputs
      3. 7.4.3 Clamp Diode Structure
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
    3. 8.3 Design Requirements
      1. 8.3.1 Power Considerations
      2. 8.3.2 Input Considerations
      3. 8.3.3 Output Considerations
    4. 8.4 Detailed Design Procedure
    5. 8.5 Application Curve
    6. 8.6 Power Supply Recommendations
    7. 8.7 Layout
      1. 8.7.1 Layout Guidelines
      2. 8.7.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • RKS|20
  • DGS|20
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted); typical values measured at TA = 25°C
PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT
VOH IOH = -50 µA 1.5 V 1.4 1.49 V
1.8 V 1.7 1.79
2.5 V 2.4 2.49
3 V 2.9 2.99
4.5 V 4.4 4.49
5.5 V 5.4 5.49
IOH = -1 mA 1.8 V 1.44
IOH = -2 mA 2.5 V 2
IOH = -4 mA 3 V 2.4
IOH = -12 mA 3 V 2.4
IOH = -24 mA 4.5 V 3.7
IOH = -24 mA 5.5 V 4.7
IOH = -75 mA 5.5 V
IOH = -50 mA 5.5 V 3.85
VOL IOL = 50 µA 1.5 V 0.01 0.1 V
1.8 V 0.01 0.1
2.5 V 0.01 0.1
3 V 0.01 0.1
4.5 V 0.01 0.1
5.5 V 0.01 0.1
IOL = 1 mA 1.8 V 0.36
IOL = 2 mA 2.5 V 0.5
IOL = 4 mA 3 V 0.5
IOL = 12 mA 3 V 0.5
IOL = 24 mA 4.5 V 0.5
IOL = 24 mA 5.5 V 0.5
IOL = 50 mA 5.5 V 1.65
IOL = 75 mA 5.5 V 1.65
II VI = 5.5 V or GND 0 V to 5.5 V ±1 µA
IOZ VO = VCC or GND 5.5 V ±5 µA
ICC VI = VCC or GND, IO = 0 5.5 V 20 µA
CI VI = VCC or GND 5 V 9 pF
CO VO = VCC or GND 5 V 15 pF
CPD(1)(2) F = 1 MHz 5 V 60 pF
CPD is used to determine the dynamic power consumption, per channel
PD = VCC2 × FI × (CPD + CL) where FI= input frequency, CL= output load capacitance, VCC= supply voltage