SCLS425G June   1998  – November 2023 SN74AHC174

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  Timing Requirements, VCC = 3.3 V ± 0.3 V
    7. 6.7  Timing Requirements, VCC = 5 V ± 0.5 V
    8. 6.8  Switching Characteristics, VCC = 3.3 V ± 0.3 V
    9. 6.9  Switching Characteristics, VCC = 5 V ± 0.5 V
    10. 6.10 Operating Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Power Supply Recommendations
    2. 9.2 Layout
      1. 9.2.1 Layout Guidelines
      2. 9.2.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support (Analog)
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DB|16
  • PW|16
  • N|16
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Timing Requirements, VCC = 5 V ± 0.5 V

over recommended operating free-air temperature range (unless otherwise noted)
TA = 25°C SN74AHC174 UNIT
MIN MAX MIN MAX
tw Pulse duration CLR low 5 5 ns
CLK high or low 5 5
tsu Setup time before CLK↑ Data 4.5 4.5 ns
CLR inactive 2.5 2.5
th Hold time, data after CLK↑ 0.5 0.5 ns