over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage | –0.5 | 4.6 | V |
| VI | Input voltage(2) | –0.5 | 4.6 | V |
| Continuous channel current | | 128 | mA |
| IIK | Input clamp current | VI/O < 0 | | –50 | mA |
| TJ | Junction temperature | | 150 | °C |
| Tstg | Storage temperature | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute Maximum Ratings do not imply functional operation of the device
at these or any other conditions beyond those listed under Recommended Operating
Conditions. If used outside the Recommended Operating Conditions but within the
Absolute Maximum Ratings, the device may not be fully functional, and this may
affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) The input and output negative-voltage ratings may be exceeded if the input and
output clamp-current ratings are observed.