over operating free-air temperature range (unless otherwise noted)
(1) | | | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage range | | –0.5 | 6.5 | V |
| VI | Input voltage range(2) | | –0.5 | 6.5 | V |
| VO | Voltage range applied to any output in the high-impedance or power-off state(2) | –0.5 | 6.5 | V |
| VO | Voltage range applied to any output in the high or low state(2)(3) | –0.5 | VCC + 0.5 | V |
| IIK | Input clamp current | VI < 0 | | –50 | mA |
| IOK | Output clamp current | VO < 0 | | –50 | mA |
| IO | Continuous output current | | | ±50 | mA |
| Continuous current through VCC or GND | | | ±100 | mA |
| Tstg |
Storage
temperature |
-65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device
damage. Absolute maximum ratings do not imply
functional operation of the device at these or any
other conditions beyond those listed under
Recommended Operating Conditions. If
briefly operating outside the Recommended
Operating Conditions but within the
Absolute Maximum Ratings, the device may
not sustain damage, but it may not be fully
functional. Operating the device in this manner
may affect device reliability, functionality,
performance, and shorten the device lifetime.
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The value of VCC is provided in the Recommended Operating Conditions table.