over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage(2) | | 7 | V |
| Voltage range at any bus terminal | –10 | 15 | V |
| VI | Enable input voltage | | 5.5 | V |
| TJ | Operating virtual junction temperature | | 150 | °C |
| Tstg | Storage temperature range | –65 | 150 | °C |
| Lead temperature
1.6mm (1/16 inch) from case for 10 seconds | | 260 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent
device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) All voltage values, except differential input/output bus voltage, are with respect to network ground terminal.