4 Revision History
Changes from * Revision (July 2017) to A Revision
-
Added EN VIH MIN 1.8 V to the Recommended Operating Conditions for DBV packageGo
-
Changed RDS(on) TYP from 72 to 66 and added MAX 77 for DBV packageGo
-
Added RDS(on) MAX 77 for DBV package for 2-A rated output, –40°C ≤ (TJ , TA) ≤ 85°C conditionGo
-
Changed RDS(on) TYP from 72 to 66 for DBV package for 2-A rated output, and added MAX 106 Go
-
Added EN Threshold, input rising MAX 1.8 V for DBV package Go