SLVSGS9G March 2023 – October 2025 TPS61299
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
TPS61299xA is auto pass through when disabled, but after start up, the function is the same with TPS61299x device.The A version device also support normal mode and fast mode operation. Set the VSEL according to Table 8-4 to select different target output voltage during fast mode operation. TI recommends to add a tantalum electrolytic capacitor of 150µF to 220µF to depress the inverse current during the shutdown process. Table 8-4 lists the design parameters.