SLVSGV3A April   2022  – July 2022 ESD341

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1.     Absolute Maximum Ratings
    2. 6.1 ESD Ratings—JEDEC Specification
    3. 6.2 ESD Ratings—IEC Specification
    4.     Recommended Operating Conditions
    5. 6.3 Thermal Information
    6. 6.4 Electrical Characteristics
    7. 6.5 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 IEC 61000-4-2 ESD Protection
      2. 7.3.2 IEC 61000-4-5 Surge Protection
      3. 7.3.3 IO Capacitance
      4. 7.3.4 DC Breakdown Voltage
      5. 7.3.5 Ultra Low Leakage Current
      6. 7.3.6 Low ESD Clamping Voltage
      7. 7.3.7 Supports High Speed Interfaces
      8. 7.3.8 Industrial Temperature Range
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Signal Range
        2. 8.2.2.2 Operating Frequency
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Support Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  12. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Tape and Reel Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DPL|2
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Features

  • IEC 61000-4-2 level 4 ESD protection
    • 30 kV contact discharge
    • 30 kV air gap discharge
  • IEC 61000-4-5 surge protection
    • 5.4 A (8/20 µs)
  • IO capacitance:
    • 0.66 pF (typical)
  • DC breakdown voltage: ±6.2 V (typical)
  • Ultra low leakage current: 100 nA (maximum)
  • Low ESD clamping voltage: 10.2 V at 16 A TLP
  • Low insertion loss: 5 GHz (–3 dB bandwidth, DPL)
  • Supports high speed interfaces up to 3.4 Gbps
  • Industrial temperature range: –40°C to +125°C
  • Space-saving industry standard 0201 footprint