JAJSEG3G July   1991  – April 2024 SN75ALS174A

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Rating Table
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 Documentation Support
    2. 8.2 ドキュメントの更新通知を受け取る方法
    3. 8.3 サポート・リソース
    4. 8.4 Trademarks
    5. 8.5 静電気放電に関する注意事項
    6. 8.6 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • N|16
  • DW|20
  • PW|20
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted)
PARAMETERTEST CONDITIONSMINTYP(1)MAXUNIT
VIKInput clamp voltageII = –18mA–1.5V
VOOutput voltageIO = 006V
|VOD1|Differential output voltageIO = 01.56V
|VOD2|Differential output voltageRL = 100ΩSee Note Figure 6-11/2 VOD1 or 2(2)V
RL = 54Ω1.52.55V
|VOD3|Differential output voltageSee (5)1.55V
Δ|VOD|Change in magnitude of differential output voltage(3)RL = 54Ω or 100ΩSee Figure 6-1±0.2V
VOCCommon-mode output voltage(4)RL = 54Ω or 100ΩSee Figure 6-13V
–1V
Δ|VOC|Change in magnitude of common-mode output voltage(3)RL = 54Ω or 100ΩSee Figure 6-1±0.2V
IOOutput current with power offVCC = 0, VO = –7V to 12V±100µA
IOZHigh-impedance-state output currentVO = –7V to 12V±100µA
IIHHigh-level input currentVI = 2.7V20µA
IILLow-level input currentVI = 0.4V–100µA
IOSShort-circuit output currentVO = –7V to 12V±250mA
ICCSupply current (all drivers)No loadOutputs enabled3655mA
Outputs disabled1630mA
All typical values are at VCC = 5V and TA = 25°C.
The minimum VOD2 with a 100Ω load is either 1/2VOD1 or 2V, whichever is greater.
Δ|VOD| and Δ|VOC| are the changes in magnitude of VOD and VOC, respectively, that occur when the input is changed from a high level to a low level.
In ANSI Standard EIA/TIA-422-B, VOC, which is the average of the two output voltages with respect to ground, is called output offset voltage, VOS.
See EIA Standard RS-485, Figures 3-5, Test Termination Measurement 2.