SBOK050 November   2023 OPA4H014-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
  5. 2Texas Instruments Enhanced Product Qualification and Reliability Report
  6. 3Space Enhanced Plastic Production Flow
  7. 4Qualification by Similarity (Qualification Family)
  8. 5Outgas Test Report

Outgas Test Report

Outgassing testing was performed on leadless units at Pacific Testing Laboratories in Valencia, California. 35 devices were submitted with leads removed, of which a total sample mass of approximately 1 g was used (n≥15). A total mass loss (TML) of 1.00% and collected volatile condensable material (CVCM) of 0.10% were used as screening levels for rejection of spacecraft materials. The outgas test was performed in a vacuum environment of less than 5 × 10 –5 torr according to ASTM E 595, for a duration of 24 hours, at 125°C. The TML, CVCM, and the amount of Water Vapor Recovered (WVR) were measured after the test.

Table 5-1 Outgas Test Results
Sample TML (%) CVCM (%) WVR (%)
OPA4H014-SEP 0.09 0.03 0.04