A series of measurements was taken to experimentally determine the upper distance boundary. CH1: START, CH2: COMPIN, CH3: STOP.
The standard ToF measurement mode was used in anticipation of a longer ToF, however, it was not necessary. Since the maximum range is limited by echo attenuation, a similar result would be seen in short ToF mode. In the standard mode, noise is seen on the COMPIN pin during the auto-zero period, this should not be mistaken for the received echo. The end of the reliable range was found to be about 10cm. Just beyond 10cm, the signal is too weak to be reliably trigger a stop pulse with the 35 mV threshold.
In Figure 4-4, the signal is too weak to trigger a stop.