SLUUBD4A April 2016 – November 2022 BQ27220
| Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | |
|---|---|---|---|---|---|---|---|---|
| High Byte | RSVD | RSVD | RSVD | RSVD | Default Seal | NR | RSVD | RSVD |
| Default | 0 | 0 | 0 | 1 | 0 | 0 | 0 | 0 |
| 0x10 | ||||||||
| Low Byte | INT_BREM | INT_BATL | INT_STATE | INT_OCV | RSVD | INT_OT | INT_POL | INT_FOCV |
| Default | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
| 0x00 | ||||||||
| High Byte | ||
| Default Seal = | Seal during POR. | |
| 0 = No Seal after POR (default) | ||
| 1 = Seal after POR | ||
| NR = | Non Removable | |
| Low Byte | ||
| INT_BREM = | The GPOUT pulses 1 ms when the battery is removed and [BIEnable] = 1. Enabled when set. | |
| INT_BATL = | Enables toggle of the GPOUT pin upon TDA getting set | |
| INT_STATE = | Enables the SOC_INT function to pulse the GPOUT pin on current direction change | |
| INT_OCV = | Enables the SOC_INT function to generate a pulse due to OCV command | |
| RSVD = | Reserved | |
| INT_OT = | Enables the SOC_INT function to generate a pulse due to overtemperature conditions in conjunction with the assertion of BatteryStatus()[OTC or OTD] | |
| INT_POL = | GPOUT pin polarity control. Active-low is 0. Active-high is 1. | |
| INT_FOCV = | The GPOUT pulses during the first measurement if this bit is set. | |