SLUUCI8A November 2023 – October 2026 BQ76905
| Class | Subclass | Name | Type | Min | Max | Default | Unit |
|---|---|---|---|---|---|---|---|
| Protections | Current | Overcurrent in Charge Protection Delay | U1 | 0 | 255 | 58 | Varying |
Description: This parameter sets the Overcurrent in Charge Protection delay.
0x00 = Fastest delay (approximately 0.46ms)
0x01 - 0x40 = 1.22ms to 20.435ms in steps of 0.305ms
0x41 - 0x80 = 22.875ms to 176.595ms in steps of 2.44ms
0x81 - 0xC0 = 181.475ms to 488.915ms in steps of 4.88ms
0xC1 - 0xFF = 498.675ms to 1103.795 ms in steps of 9.77ms