SPRUI97E May 2017 – September 2025
The 3.3-V clamp circuit is tuned too close such that if the 1.8-V supply is 5% low and the 3.3-V supply is 5% high, the clamp begins conducting. Replacing resistors R897 and R801 with a 24.3-KΩ resistor provides the proper tolerance, so the circuit will start conducting at a delta voltage of 1.75 V rather than the current setting of 1.5 V.