SBAS644C April 2018 – December 2025 DRV5056
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS(1) | MIN | TYP | MAX | UNIT | ||
|---|---|---|---|---|---|---|---|
| VQ | Quiescent voltage | B = 0 mT, TA = 25°C | DRV5056A1/Z1 | 0.535 | 0.6 | 0.665 | V |
| DRV5056A2/Z2, DRV5056A6 | 0.54 | 0.6 | 0.66 | ||||
| DRV5056A3/Z3, DRV5056A4/Z4 | 0.55 | 0.6 | 0.65 | ||||
| DRV5056A8 | 0.55 | 0.6 | 0.65 | V | |||
| VQΔT | Quiescent voltage temperature drift | B = 0 mT, TA = –40°C to 125°C versus 25°C |
VCC = 5 V | 0.08 | V | ||
| VCC = 3.3 V | 0.04 | ||||||
| VQΔT | Quiescent voltage temperature drift | B = 0 mT, TA = –40°C to 125°C versus 25°C |
DRV5056A8 | 0 | V | ||
| VQΔL | Quiescent voltage lifetime drift | High-temperature operating stress for 1000 hours | < 0.5% | ||||
| S | Sensitivity | VCC = 5 V, TA = 25°C |
DRV5056A1/Z1 | 190 | 200 | 210 | mV/mT |
| DRV5056A2/Z2, DRV5056A6 | 95 | 100 | 105 | ||||
| DRV5056A3/Z3 | 47.5 | 50 | 52.5 | ||||
| DRV5056A4/Z4 | 23.8 | 25 | 26.2 | ||||
| DRV5056A8 | 63.3 | 66.6 | 69.9 | ||||
| VCC = 3.3 V, TA = 25°C |
DRV5056A1/Z1 | 114 | 120 | 126 | |||
| DRV5056A2/Z2, DRV5056A6 | 57 | 60 | 63 | ||||
| DRV5056A3/Z3 | 28.5 | 30 | 31.5 | ||||
| DRV5056A4/Z4 | 14.3 | 15 | 15.8 | ||||
| DRV5056A8 | 38.0 | 40 | 42 | ||||
| BL | Linear magnetic sensing range(2) | VCC = 5 V, TA = 25°C |
DRV5056A1/Z1 | 20 | mT | ||
| DRV5056A2/Z2, DRV5056A6 | 39 | ||||||
| DRV5056A3/Z3 | 79 | ||||||
| DRV5056A4/Z4 | 158 | ||||||
| DRV5056A8 | 64 | ||||||
| VCC = 3.3 V, TA = 25°C |
DRV5056A1/Z1 | 19 | |||||
| DRV5056A2/Z2, DRV5056A6 | 39 | ||||||
| DRV5056A3/Z3 | 78 | ||||||
| DRV5056A4/Z4 | 155 | ||||||
| DRV5056A8 | 65 | ||||||
| VL | Linear range of output voltage(3) | VQ | VCC – 0.2 | V | |||
| STC | Sensitivity temperature compensation for magnets(4) | DRV5056A6 | 0.05 | 0.12 | 0.19 | %/°C | |
| DRV5056A1, DRV5056A2, DRV5056A3, DRV5056A4, DRV5056A8 | 0.12 | %/°C | |||||
| DRV5056Z1, DRV5056Z2, DRV5056Z3, DRV5056Z4 | 0 | %/°C | |||||
| SLE | Sensitivity linearity error(3) | VOUT is within VL | ±1% | ||||
| SRE | Sensitivity ratiometry error(5) | TA = 25°C, with respect to VCC = 3.3 V or 5 V |
-2.5% | 2.5% | |||
| SΔL | Sensitivity lifetime drift | High-temperature operating stress for 1000 hours | < 0.5% | ||||