SBASB94 August 2025 AMC1333M10-Q1
PRODUCTION DATA
Do not leave the inputs of the AMC1333M10-Q1 unconnected (floating) when the device is powered up. If either modulator input is left floating, there is a possibility of input bias current driving this input beyond the specified common-mode input voltage range. If both inputs are beyond that range, the gain of the front-end diminishes and the output bitstream is not valid.
Connect the high-side ground (AGND) to INN, either by a hard short or through a resistive path. A DC current path between INN and AGND is required to define the input common-mode voltage. Take care not to exceed the input common-mode range, as specified in the Recommended Operating Conditions table. For best accuracy, route the ground connection as a separate trace that connects directly to the sense resistor rather than shorting AGND to INN directly at the input to the device. See the Layout section for more details.
Do not connect protection diodes to the inputs (INP or INN) of the AMC1333M10-Q1. High diode leakage current introduces significant measurement error especially at high temperatures. The input pin is protected against high voltages by the internal ESD protection circuit and the high impedance of the external restive divider.