If a variable is used in many locations, the variable can be implemented in the schematic as a parameter. Through the PSpice® Part Search (built in library), which can be accessed through Place > PSpice Component… > Search…, search for PARAM and double-click to place on schematic.
Press “ESC” to stop multiple placements. Figure 4-6 shows the PARAM component placed on the schematic.
Once placed, double-click on the PARAMETERS component to open the Property Editor in another tab. Optionally, to display properties in a vertical fashion, as seen in Figure 4-7, select Pivot.
Select New Property… and select a name and a default value for the parameter as seen in Figure 4-8. Select the checkbox Display [ON/OFF] to show the new parameter in the schematic. Select Apply to continue to add multiple parameters. Alternatively, select OK to add only one parameter.
The selection of Display [ON/OFF], allows the user to choose display settings. Select the Display Format to be Name and Value. The default font and size, Arial 7, is small when presenting on a projector. For an automated project, commonly used parameters can be simple to find in a schematic if implemented with a larger font size. In the example shown in Figure 4-9, font size of 12 was selected.
As previously mentioned, if adding multiple parameters, select Apply and create as many new parameters as the project requires. Figure 4-10 shows different parameters that were added and the default value of each parameter.
Once a parameter is declared in the schematic, the user can call the parameter by placing curly brackets around the name in the Value of a component. In Figure 4-11, the value of R1 is changed from 1kΩ to the variable value corresponding to the parameter RISO.
If there are commonly used names for the components in a circuit, change the Part Reference to reflect that.
A probe is added for the parameter to be called in the output simulator window. To add a probe to a parameter, the following text must be added in the schematic through Place > Text or keyboard shortcut T, @PSpice: .probe P(parameter name). The use-case for this implementation is when a parameter is needed in post-processing equations, discussed in detail in Section 5.2. In Figure 4-13, the parameter used in calculations was CLOAD, this procedure can be repeated for multiple parameters as needed. The font size was increased to 12.