SBOS301C May 2004 – December 2025 LOG114
PRODUCTION DATA
|
PIN |
TYPE |
DESCRIPTION |
|
|---|---|---|---|
|
NAME |
NO. |
||
|
COM |
7 |
Input |
Reference Voltage for the differential amplifier |
|
+IN4 |
10 |
Input |
Auxiliary operational amplifier voltage non-inverting input |
|
–IN4 |
11 |
Input |
Auxiliary operational amplifier voltage inverting input |
|
+IN5 |
13 |
Input |
Auxiliary operational amplifier voltage non-inverting input |
|
–IN5 |
14 |
Input |
Auxiliary operational amplifier voltage inverting input |
|
NC |
2 |
N/A |
No Connection |
|
I1 |
4 |
Input |
Current input for logarithm numerator |
|
I2 |
3 |
Input |
Current input for logarithm denominator |
|
V+ |
8 |
Power |
Positive supply voltage |
|
V- |
6 |
Power |
Negative supply voltage |
|
VCM IN |
5 |
Input |
Input common-mode voltage |
|
VLOGOUT |
9 |
Output |
Logarithmic difference amplifier output |
|
VO4 |
12 |
Output |
Auxiliary operational amplifier voltage output |
|
VO5 |
15 |
Output |
Auxiliary operational amplifier voltage output |
|
VREF |
16 |
Power |
2.5V reference voltage |
|
VREFGND |
1 |
Ground |
Reference voltage ground |
|
Thermal Pad |
PAD |
— |
Thermal Pad. Connect to V- |