The design requirements for the circuit shown in Figure 7-1 are listed in Table 7-3.
| DESIGN PARAMETER | EXAMPLE VALUE |
|---|---|
| Power-supply voltage (VS) | 5V |
| Bus supply rail (VCM) | 12V |
| Bus supply rail overvoltage fault threshold | 14V |
| Average Current | 5A |
| Overcurrent fault threshold (IMAX) | 9A |
| Temperature | 40ºC |
| Charge Accumulation Period | 1 hour |