SBOU301A July 2023 – January 2024 LOG200
Figure 3-2 details the default jumper settings of the LOG200EVM. Table 3-3 explains the configuration for these jumpers.
Figure 2-2 LOG200EVM Default Jumper Settings| Jumper | Function | Default Position | Description |
|---|---|---|---|
| J7 | Out_A SMA J5 reference | Shunt 2-3 | Shunt 2-3: SMA connector J3 referred to GND Shunt 1-2: SMA connector J3 referred to REFA |
| J8 | VCM Select | Shunt 1-2 | Shunt 1-2: VCM input connected to GND Shunt 3-4: Connects VCM input to 2.5V reference |
| J9 | VS– connection | Open | Open: Bipolar supply configuration Shunt 1-2: Connects VS– to GND for unipolar supply configuration |
| J11 | REF A Select | Shunt 7-8 | Shunt 1-2: Sets log voltage REFA to external voltage through J10 Shunt 3-4: Sets REFA to REF25 Shunt 5-6: Sets REFA to REF165 Shunt 7-8: Sets REFA to GND |
| J15 | Secondary op-amp input | Shunt 1-2 | Shunt 1-2: Connects Aux AMP+IN to OUTA Shunt 3-4: Connects Aux AMP -IN to OUTA |