SCASE76 February 2025 SN74ACT11-Q1
PRODUCTION DATA
| PARAMETER | FROM (INPUT) | TO (OUTPUT) | LOAD CAPACITANCE | VCC | -40°C to 125°C | UNIT | ||
|---|---|---|---|---|---|---|---|---|
| MIN | TYP | MAX | ||||||
| tPLH | A, B, or C | Y | CL = 50pF | 5V | 5 | 8 | ns | |
| tPHL | A, B, or C | Y | CL = 50pF | 5V | 5.2 | 7.8 | ns | |
| tr | Y | CL = 50pF | 5V | 2.8 | 4.7 | ns | ||
| tf | 5V | 2.6 | 4.1 | ns | ||||