SLAU895A July 2023 – March 2026
By default, the barrel jack connector J43 is used to power VBAT on both TAS2572 channels. Supply 2.4V-5.5V on this connector.
Alternatively, independent connectors can be used for the external VBAT supply for both the channels – VBAT1_IN and VBAT2_IN. Jumpers J39 and J46 must be open to disconnect VBAT to VBAT1_IN form J43 input, and similarly J41 and J49 must be open to disconnect VBAT to VBAT2_IN from J43 input.
For channel-1, external VBAT1_IN can be connected between connectors J30 (or J72) and J31 (or J73) as shown in Figure 7-1.
For channel-2, external VBAT2_IN can be connected between connectors J55 (or J58) and J3 (or J59) as shown in Figure 7-1.