SLFS078D October 2006 – January 2026 TLC555-Q1
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| Supply voltage sensitivity of timing interval | VDD = 5V to 15V, CT = 0.1μF RA = RB = 1kΩ to 100kΩ (1) |
0.1 | 0.5 | %/V | ||
| tr | Output pulse rise time | RL = 10MΩ, CL = 10pF | 20 | 75 | ns | |
| tf | Output pulse fall time | RL = 10MΩ, CL = 10pF | 15 | 60 | ns | |
| fmax | Maximum frequency in astable mode | RA = 470Ω, CT = 200pF RB = 200Ω (1) | 1.2 | 2.1 | MHz | |