| FAULT FLOATING |
| LED open-circuit |
VISNx – VSENSEx < V(OPEN_th_rising) |
On |
t(OPEN_deg) |
Constant-current pulldown |
All channels turned off. Pulsed pullup retry of faulty channel. |
Auto recover |
| LED short-to-GND |
VSENSEx < V(SG_th_rising) |
On |
t(SG_deg) |
All channels turned off. Pulsed pullup retry of faulty channel. |
| LED short-to-battery |
VISNx – VSENSEx < V(OPEN_th_rising) |
On or off |
t(OPEN_deg) |
All channels turned off. Faulty channel pulsed pullup retry of faulty channel. |
| Overtemperature |
TJ > T(TSD) |
On or off |
|
All channels turned off. |
| FAULT EXTERNALLY PULLED UP |
| LED open-circuit |
VISNx – V SENSEx < V(OPEN_th_rising) |
On |
t(OPEN_deg) |
Externally pulled up with internal constant-current pulldown |
Only faulty channel turned off. Pulsed pullup retry of faulty channel. |
Auto recover |
| LED short-to-GND |
V SENSEx < V(SG_th_rising) |
On |
t(SG_deg) |
Only faulty channel turned off. Pulsed pullup retry of faulty channel. |
| LED short-to-battery |
V ISNx – V(SENSEx) < V(OPEN_th_rising) |
On or off |
t(OPEN_deg) |
Only faulty channel turned off. Pulsed pullup retry of faulty channel. |
| Overtemperature |
TJ > T(TSD) |
On or off |
|
All channels turned off. |
| FAULT EXTERNALLY PULLED DOWN |
| All outputs disabled |