over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
|---|
| VCC | Supply voltage range | 2.7 | 15 | V |
| VID | Differential input voltage(2) | | ±1V | V |
| VIN | Input voltage range(3) | VCC– – 0.3 | VCC+ + 0.3 | V |
| TJ | Maximum junction temperature | | 150 | °C |
| Tstg | Storage temperature range | –65 | 150 | °C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under Recommended
Operating Conditions. If used outside the Recommended Operating Conditions
but within the Absolute Maximum Ratings, the device may not be fully functional,
and this may affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) Differential voltages for the non-inverting input terminal are with respect to
the inverting input terminal.
(3) The input and output voltages must never exceed VCC +0.3V.