Summary

This article provides the design considerations of BQ769x2 current sensing. The current accuracy can be calculated before starting the design and improved following the recommendations in this article. If the diagnostic is required for current sensing circuit, a diagnostic proposal is also recommended. This article also shows the example to read the accumulated charge integration that can be used for SoC calculation or other decision purposes.