The recommended input supply voltage (VCCI) for UCC21225A is from 3V to 18V. The lower end of the output bias supply voltage (VDDA/VDDB) range is governed by the internal undervoltage lockout (UVLO) protection feature of the device. VDD and VCCI must not fall below the respective UVLO thresholds for normal operation, or else gate driver outputs can become clamped low for >50µs by the UVLO protection feature. (For more information on UVLO see Section 7.3.1). The upper end of the VDDA/VDDB range depends on the maximum gate voltage of the power device being driven by UCC21225A, and must not exceed the recommended maximum VDDA/VDDB of 25V.
Place a local bypass capacitor between the VDD and VSS pins, with a value of from 220nF to 10µF for device biasing. It is further suggested that an additional 100nF capacitor be placed in parallel with the device biasing capacitor for high-frequency filtering. Position both capacitors as close to the device as possible. Low ESR, ceramic surface-mount capacitors are recommended.
Similarly, place a bypass capacitor between the VCCI and GND pins. Given the small amount of current drawn by the logic circuitry within the input side of UCC21225A, this bypass capacitor has a minimum recommended value of 100nF.