SLUSFR2 November 2024 BQ21088
PRODUCTION DATA
The device has an internal pulldown on the SYS pin which is enabled in the following cases:
|
STATE |
NOTES |
|---|---|
|
Shipmode |
Pulldown on SYS is enabled once the device enters the shipmode and after disconnecting the BATFET |
|
HW_RESET |
Pulldown on SYS is enabled after the BATFET and ILIM FET are disconnected and retained until the autowake timer expires |
|
SYS_MODE = 11 (SYS pulldown mode) |
Pulldown on SYS is enabled after the BATFET and ILIM FET are disconnected and retained till either an I2C transaction – changing SYS_MODE or a hardware reset – is given or VIN is toggled. |