The LM74912Q1EVM is configured by default for evaluating 12-V automotive reverse battery protection with switched output to disconnect power path or clamp the output. For evaluation of input voltages greater than 35V, the input TVS (D1) has to be removed and an appropriate TVS has to be installed to clamp the input transients to less than 70V.
Table 2-1 LM74912Q1EVM Evaluation Board Options and Setting| Part Number | EVM Function | Vin Range | Vin UVLO | Vin OVP | ENABLE (EN) | Overcurrent Protection | Features |
|---|