SLVK144 august   2023 TL1431-SP

PRODUCTION DATA  

  1.   1
  2.   2
  3.   Trademarks
  4. 1Overview
  5. 2Test Procedures
  6. 3Facility
  7. 4Results
  8. 5Data Sheet Electrical Parameters and Associated Tests
  9.   A Appendix: Test Results

Data Sheet Electrical Parameters and Associated Tests

at specified free-air temperature, IKA = 10 mA (unless otherwise noted)

ParameterTest ConditionsTA(2)MinTypMaxUnitTest Numbers
VI(ref)Reference input voltageVKA = VI(ref)25°C247525002540mV
Full range246025507.0
VI(dev)Deviation of reference input voltage over full temperature range(3)VKA = VI(ref)Full range1755(1)mV
ΔVI(ref)/ΔVKARatio of change in reference input voltage to the change in cathode voltageΔVKA = 3 V to 36 VFull range-1.1-2mV/V16.0
II(REF)Reference input currentR1 = 10 kΩ, R2 = ∞25°C1.52.5μA
Full range515.2
II(dev)Deviation of reference input current over full temperature range (3)R1 = 10 kΩ, R2 = ∞Full range0.53(1)μA
IminMinimum cathode current for regulationVKA = VI(ref)25°C0.451mA11.0
IoffOff-state cathode currentVKA = 36 V, VI(ref) = 025°C0.180.5μA
Full range22.0
|zKA| Output impedance(4) VKA = VI(ref), f ≤ 1 kHz, IKA = 1 mA to 100 mA Full range 0.2 0.4 14.1
  1. On products compliant to MIL-PRF-38535, this parameter is not production tested.
  2. Full range is –55°C to +125°C.
  3. The deviation parameters VI(dev) and II(dev) are defined as the differences between the maximum and minimum values obtained over the rated temperature range. For more details, see the device data sheet.
  4. Please see device data sheet for details on output impedance.