SLVK356 November   2026 ISOS510-SP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1 Introduction
  5. 2 Single-Event Effects (SEE)
  6. 3 Device and Test Board Information
  7. 4 Irradiation Facility and Setup
  8. 5 Test Setup and Procedures
  9. 6 Single-Event Latch-up (SEL) Results
  10. 7 Single-Event Transients (SET) Results
  11. 8 Event Rate Calculations
  12. 9 Summary
  13. 10References

Single-Event Transients (SET) Results

SET are defined as heavy-ion-induced transients upsets on the VOUT of the ISOS510-SP.

Testing was performed at room temperature (no external temperature control applied). The heavy-ions species used for SET testing were 169Tm & 109Ag at 19.5MeV/nucleon at MSU, and 84Kr, 40Ar and 14N at 15MeV/nucleon at TAMU. 169Tm, 109Ag, 84Kr, 40Ar, and 14N for LETEFF from 1.34 to 75MeV×cm2/mg, for more details refer to Table 4-1. Flux of 105 ions×cm2/s and a fluence of 1 × 107 ions/cm2, per run were used for the characterization of the SET.

Table 7-1 shows the signal size, sample rate, trigger type, value, and signal for all scopes.

Table 7-1 Scope Settings
Scope ModelTrigger SignalTrigger TypeTrigger ValueRecord LengthSample Rate
PXIe-5172VOUTWindow±3%10k100MS/s
±5%

For the VIN of approximately 4.1V and VCE of 3.3V with a VOUT of approximately 1V, five units were characterized from 75MeV down to 1.34MeV. 169Tm was used to achieve LETEFF = 75MeV and 14N was used to achieve LETEFF = 1.34MeV. A PXIe-5172 scope was used to monitor the VOUT signals of the ISOS510-SP with VOUT triggering off a 3% and 5% window. Table 7-2 summarizes the results for the four units tested.

Typical Low and High observed VOUT transients are shown in Figure 7-1 and Figure 7-2 respectively. Figure 7-3 show that although the signal goes beyond the 3% window, the signal recovers back to nominal and the device continues to operate properly.

Table 7-4 shows the Weibull fit parameters and the Weibull fit plot. Figure 7-6 and Figure 7-7 shows the Weibull fit plots for the VOUT 3% and 5% triggers.

Table 7-2 Summary of ISOS510-SP SET Test Condition and Results
RUN #UNIT #FacilityIonLETEFF (MeV×cm2/mg)FLUX (ions×cm2/mg)FLUENCE (number of ions)Window TriggerPXIe-5172 VOUT SET Upsets
134MSU169Tm751.00 × 1051.00 × 1075%3590
144MSU169Tm751.00 × 1051.00 × 1073%3754
155MSU109Ag471.00 × 1051.00 × 1075%3192
165MSU109Ag471.00 × 1051.00 × 1073%3525
176TAMU84Kr30.11.00 × 1051.00 × 1075%2386
186TAMU84Kr30.11.00 × 1051.00 × 1073%2796
197TAMU40Ar8.541.00 × 1051.00 × 1075%1885
207TAMU40Ar8.541.00 × 1051.00 × 1073%2279
218TAMU14N1.341.00 × 1051.00 × 1075%690
228TAMU14N1.341.00 × 1051.00 × 1073%2021

Figure 7-1 shows the typical low observed VOUT for Run #14. Transient reached a peak of approximately 0.08V and recovered within approximately 20.5μs

 Typical Low Observed
                        VOUT Transient on Run #14 Figure 7-1 Typical Low Observed VOUT Transient on Run #14

Figure 7-2 shows the typical high observed VOUT for Run #14. Transient reached a peak of approximately 2.53V and recovered within approximately 15μs

 Typical High Observed
                        VOUT Transient on Run #14 Figure 7-2 Typical High Observed VOUT Transient on Run #14
 Overlay of all VOUT Transients on Run
                    #14 Figure 7-3 Overlay of all VOUT Transients on Run #14
  VOUT Voltage
                    Deviation Histogram Run #14 Figure 7-4 VOUT Voltage Deviation Histogram Run #14
  VOUT Transient
                    Duration Histogram Run #14 Figure 7-5 VOUT Transient Duration Histogram Run #14

Using the MFTF method, the upper-bound cross section (using a 95% confidence level) is calculated for the different SETs as shown below.

Table 7-3 Upper Bound Cross Section at 95% Confidence Interval
IonLETEFF (MeV×cm2/mg)FLUENCE (# ions)Window TriggerPXIe-5172 VOUT SET UpsetsUpper Bound Cross Section (cm2 /device)
169Tm751.00 × 1075%35903.71 × 10–4
169Tm751.00 × 1073%37543.88 × 10–4
109Ag471.00 × 1075%31923.30 × 10–4
109Ag471.00 × 1073%35253.64 × 10–4
84Kr30.11.00 × 1075%23862.48 × 10–4
84Kr30.11.00 × 1073%27962.90 × 10–4
40Ar8.541.00 × 1075%18851.97 × 10–4
40Ar8.541.00 × 1073%22792.37 × 10–4
14N1.341.00 × 1075%6907.43 × 10–5
14N1.341.00 × 1073%20212.11 × 10–4
Table 7-4 Weibull Parameters for VOUT Signal
Parameters3%5%
Cross-saturation (cm2)4.48 × 10–44.99 × 10–4
w14.9850.01
s0.260.50
 Weibull Fit for
                        VOUT 3% Trigger Figure 7-6 Weibull Fit for VOUT 3% Trigger
 Weibull Fit for
                        VOUT 5% Trigger Figure 7-7 Weibull Fit for VOUT 5% Trigger