over operating ambient temperature range (unless otherwise noted)(1)(2)
|
MIN |
MAX |
UNIT |
| Supply voltage VS pin |
t
< 400ms |
— |
42 |
V |
| Reverse polarity voltage (3) |
t
< 1 minute |
–36 |
— |
V |
| Current on GND |
t
< 2 minutes |
–100 |
250 |
mA |
| Voltage on IN and DIAG_EN pins |
|
–0.3 |
42 |
V |
| Current on IN and DIAG_EN pins |
|
–10 |
— |
mA |
| Voltage on DELAY pin |
|
–0.3 |
7 |
V |
| Current on DELAY pin |
|
–60 |
— |
mA |
| Voltage on FAULT pin |
|
–0.3 |
7 |
V |
| Current on FAULT pin |
|
–30 |
10 |
mA |
| Voltage on CL pin |
|
–0.3 |
7 |
V |
| Current on CL pin |
|
— |
6 |
mA |
| Voltage on OUT pin |
|
— |
42 |
V |
| Inductive load switch-off energy dissipation single pulse(4) |
|
— |
40 |
mJ |
| Operating junction temperature |
|
–40 |
150 |
°C |
| Storage temperature, Tstg |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under Recommended
Operating Conditions. If used outside the Recommended Operating Conditions but
within the Absolute Maximum Ratings, the device may not be fully functional, and this
may affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) All voltage values are with respect to ground.
(3) Reverse polarity condition: VIN = 0V, reverse current
< IR(2), GND pin 1kΩ resistor in parallel with diode.
(4) Test condition: VVS = 13.5V, L = 300mH, TJ
= 150°C. FR4 2s2p board, 2 × 70μm Cu, 2 × 35μm Cu. 600mm2 thermal pad
copper area.