SLVSIG4 July 2026 TVS4000
PRODUCTION DATA
The TVS4000 is specified according to the IEC 61000-4-5 standard. The IEC 61000-4-5 standards requires protection against a pulse with a rise time of 8µs and a half length of 20µs.
The TVS4000 has been tested according to IEC 61000-4-5 to pass a ±1kV surge test through a 42Ω coupling resistor and a 0.5µF capacitor. This test is a common test requirement for industrial signal I/O lines and the TVS4000 serves a protection solution for applications with the requirement.
The TVS4000 also integrates IEC 61000-4-2 level 4 ESD Protection. These combine so the device can protect against most transient conditions regardless of length or type.
For more information on TI's test methods for Surge, ESD, and EFT testing, reference TI's IEC 61000-4-x Testing application note.