SLVSJ20A February   2026  – June 2026 TMAG6184

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Magnetic Characteristics
    7. 6.7 Typical Characteristics
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Magnetic Flux Direction
      2. 7.3.2 Sensors Location and Placement Tolerances
      3. 7.3.3 Magnetic Response
      4. 7.3.4 Parameters Definition
        1. 7.3.4.1 AMR Output Parameters
        2. 7.3.4.2 Transient Parameters
          1. 7.3.4.2.1 Power-On Time
        3. 7.3.4.3 Angle Accuracy Parameters
        4. 7.3.4.4 Hall Effect Sensor Parameters
      5. 7.3.5 Safety and Diagnostics
        1. 7.3.5.1 Device Level Checks
        2. 7.3.5.2 System Level Checks
    4. 7.4 Device Functional Modes
      1. 7.4.1 Operating Modes
        1. 7.4.1.1 Active Mode
        2. 7.4.1.2 Fault Mode
  9. 8 Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Power Supply as the Reference for External ADC
      2. 8.1.2 AMR Output Dependence on Airgap Distance
      3. 8.1.3 Calibration of Sensor Errors
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Extending the Angle Range to 360 Degrees
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Operating Modes

The TMAG6184 has primarily one mode of operation when all the conditions in the Recommended Operating Conditions are met. When the part detects an internal fault, the device switches into a fault mode (safe state). Figure 7-11 shows the state transition for TMAG6184.

TMAG6184 TMAG6184 State Transition
                                                  DiagramFigure 7-11 TMAG6184 State Transition Diagram