10 Revision History
Changes from Revision A (February 2026) to Revision B (April 2026)
- Updated Absolute Maximum Ratings to include high-impedance output
voltage range VO
Go
- Updated Recommended Operating Conditions to include high-impedance
output voltage range VO
Go
- Deleted high level output current from Recommended Operating
ConditionsGo
- Deleted low level output current from Recommended Operating
ConditionsGo
- Deleted Δt/Δv Input transition rise or fall rate for VCC
= 3.3V ± 0.3V and VCC = 5V ± 0.5VGo
- Deleted VOH from Electrical
CharacteristicsGo
- Updated from Iof to IOFF in Electrical
CharacteristicsGo
- Updated tpd in Switching Characteristics CL =
15pF 1.2V ± 0.1V maximum from: 33ns to: 40.8nsGo
- Updated tpd in Switching Characteristics CL =
15pF 1.8V ± 0.15V maximum from: 5.8ns to: 6nsGo
- Updated tpd in Switching Characteristics CL =
30pF 2.5V ± 0.2V maximum from: 4.3ns to: 4.5nsGo
Changes from Revision * (October 2025) to Revision A (February 2026)
- Changed the document status from Advance Information to
Production Data
Go