SLVUCC3 January 2022
This section provides the test results of the TPS629203EVM.
Figure 5-1 Efficiency, VIN= 12 V,
VOUT = 3.3 V, FSW = 2.5 MHz and 1 MHz
Figure 5-2 Load Regulation, VIN = 12 V,
VOUT = 3.3 V, FSW = 2.5 MHz and 1 MHz
Figure 5-3 Line Regulation, VIN = 5 V–17
V, VOUT = 3.3 V, IOUT = 0 A and 300 mA, FSW = 2.5 MHz and 1
MHz
Figure 5-4 Loop Response Forced PWM VSET,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA
Figure 5-5 Output Voltage Ripple Auto PFM/PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 0 A
Figure 5-6 Output Voltage Ripple Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA
Figure 5-7 Input Voltage Ripple Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA
Figure 5-8 Enable Start-Up Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA
Figure 5-9 Enable Shutdown Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA
Figure 5-10 Enable Pre-Bias Start-Up Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 0 A
Figure 5-11 Load Transient Forced PWM VSET,
VIN = 12 V, VOUT = 3.3 V, IOUT= 100 mA–300 mA, Slew Rate
= 1 A/μs
Figure 5-12 Thermal Performance Forced PWM,
VIN = 12 V, VOUT = 3.3 V, IOUT = 300 mA, FSW =
2.5 MHz