SNVSCC2I November 2022 – August 2026 TPS389C03-Q1
PRODUCTION DATA
The TPS389C03-Q1 has three key functional modes that the device enters over the course of operation. When no power is applied to the device, the device is in the OFF state where the monitoring channels and the watchdog is inactive. Once VDD is greater than UVLO, the device enters the ACTIVE state after the BIST and OTP loading have finished. During the ACTIVE state, the device is capable of full monitoring and the watchdog is active. If a BIST failure, double-error detect (DED) during the OTP loading, thermal shutdown, or an address pin fault occurs, the device enters the FAILSAFE mode. Once in FAILSAFE, NRST and NIRQ are asserted low. To leave the FAILSAFE state, power to the TPS389C03-Q1 must be cycled. Reading register 0x30 in BANK0 provides information on the state of the device. See Table 8-12 for details. The state diagram drawn in Figure 7-30 follows the progression through each state.