STDA027 March 2026 LM2776
In the DC-DC stage, the resonant topology of the inductor-inductor-capacitor (LLC) is generally the preferred choice for achieving high efficiency and power density. However, traditional direct frequency control (DFC) struggles to enhance the control bandwidth due to a variable double pole in the control loop. Hybrid hysteretic control (HHC) addresses this limitation by regulating the energy transfer per switching cycle, enabling fast dynamic performance with a simple proportional-integral-derivative (PID) compensator.
As shown in Figure 4-6, the HHC loop combines charge mode control and direct frequency control with a compensation slope on the inner resonant capacitor voltage (VCR) loop. Figure 4-7 shows a comparison of a bode plot using DFC and one using HHC in this design. The test results indicate that the hybrid hysteretic-controlled LLC maintains a better load transient response across a wide input voltage range, while the loop bandwidth with DFC is hard to compensate due to the influence of the double pole. The reference design for PMP41081 showcases the HHC method, more details are explained in references 1, 4, and 11.
Figure 4-6 LLC With HHC Loop
A. Bode Plot with
DFC.
B. Bode Plot with
HHC.