STDA070 November 2026 MSPM33C321A-Q1
In any system where safety is a key consideration, redundancy by design is often a requirement. Safety-critical automotive systems, in particular, require fault-tolerant communication. With dual CAN FD, a single MCU can be connected to two physically independent bus networks carrying the same or mirrored traffic. If one bus suffers a fault, the MCU can automatically rely on the secondary bus, maintaining communication continuity. This approach supports ISO 26262 functional safety requirements for systems requiring ASIL B or higher ratings, without adding a secondary MCU or external redundancy logic.
Scenario: An MCU manages the adaptive variable suspension (AVS) in a high-end vehicle. The MCU must receive commands from the driver/vehicle computer and monitor local sensor data to decide the appropriate damping level based on the driving conditions.
Problem: Two primary challenges arise; the first is electrical noise resulting from actuator motors potentially corrupting data packets. The second challenge is that a single wiring fault potentially prevents the driver from changing modes or leaves the suspension stuck in an inappropriate setting.
Dual CAN FD Answer: The AVS MCU uses separate CAN FD interfaces to protect different types of information and creates a redundant data path. Interface A is dedicated to the high-priority vehicle state data and commands sent to the dampers. Interface B is dedicated to local feedback, such as actuator position sensing or road-surface vibrations; see Figure 3-3 for an illustration.
Outcome: Both problems are addressed. By separating signals, potential noise and corruption are better mitigated. Additionally, by having a second physical connection between the MCU and the suspension subsystem, if a fault or failure occurs, critical commands can still be sent and received.
Figure 3-3 Dual Interface Architecture for AVS System