SWRZ081 October   2019 CC2652P

 

  1.   1
    1.     2
    2.     3
      1.      4
      2.      5
      3.      6
    3.     7
      1.      8
    4.     9
  2.   10

Advisories Matrix

Table 1 lists all advisories, modules affected, and the applicable silicon revisions.

Table 1. Advisories Matrix

MODULE DESCRIPTION SILICON REVISIONS AFFECTED
E
Radio Advisory Radio_01 — Proprietary Radio Modes: Spurious Emissions Can Affect Regulatory Compliance Yes
Radio Advisory Radio_02 — High-Power PA Operation at Temperatures Below -20°C May Affect the 32-kHz Crystal Oscillator Yes
Power Advisory Power_03 — Increased Voltage Ripple at Low Supply Voltages When DC/DC Converter is Enabled Yes
PKA Advisory PKA_01 — Public Key Accelerator (PKA) Interrupt Line is Always High When Module is Enabled and PKA is Idle Yes
PKA Advisory PKA_02 — Public Key Accelerator (PKA) RAM is Not Byte Accessible Yes
I2C Advisory I2C_01 — I2C Module Master Status Bit is Set Late Yes
I2S Advisory I2S_01 — I2S Bus Faults are Not Reported Yes
CPU Advisory CPU_01 — Arm® Errata #838869: Store Immediate Overlapping Exception Return Operation Might Vector to Incorrect Interrupt Yes
CPU Advisory CPU_02 — Arm® Errata #752770: Interrupted Loads to SP Can Cause Erroneous Behavior Yes
CPU Advisory CPU_03 — Arm® Errata #776924 VDIV or VSQRT Instructions Might Not Complete Correctly When Very Short ISRs are Used Yes
CPU, System Advisory CPU_Sys_01 — The SysTick Calibration Value (Register Field CPU_SCS.STCR.TENMS) Used to Set Up 10-ms Periodic Ticks is Incorrect When the System CPU is Running Off Divided Down 48-MHz Clock Yes
System Advisory Sys_01 — Device Might Boot Into ROM Serial Bootloader When Waking Up From Shutdown Yes
System Controller Advisory SYSCTRL_01 — Resets Occurring in a Specific 2-MHz Period During Initial Power Up are Incorrectly Reported Yes