TIDT316 December 2022
Figure 2-4 Output Voltage vs Input
Voltage of Power-StageThe measurement for line regulation data was gathered for efficiency and loss.
Figure 2-5 Efficiency and Loss vs Input
Voltage of Power-StageThe irregularity in the curves at 11.5-V to 13-V input voltage is related to the measurement range change from the input current.