TIDT439 March   2025

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Key System Specifications
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Test Setup
    5. 1.5 Power Up Procedure
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
  7. 3Waveforms
    1. 3.1 Start-up Waveform
    2. 3.2 Input Current Waveform
    3. 3.3 Load Transients
    4. 3.4 AC Drop Test
    5. 3.5 THD and PF
    6. 3.6 E-Meter Performance

Key System Specifications

Table 1-1 Key System Specifications
Parameter Specifications Unit
Input Voltage 90–265 VRMS
Line Frequency 50 or 60 Hz
Input Current (Max) 16 A
Output Voltage 385 V
Output power at 230VAC 3.6 kW
Output power at 115VAC 1.8 kW