Página principal
Videoteca

Hardening a meter against magnetic tamper attacks: Cap-drop based high-side power supplies

00:05:35 | 12 APR 2017

In order to use the AMC1304 for isolated shunt sensing, it is necessary to provide power to the high-side power supply of the AMC1304. One option for this high-side power supply is to use a cap-drop supply to power the AMC1304’s high side from Mains. This module covers the pros and cons of using a cap drop power supply to power the high-side of a AMC1304. Details will be provided on the TIDA-01094 reference design, which uses a cap-drop power supply to power the high-side of the AMC1304.

Medios

  • arrow-right Isolated shunt reference design with cap-drop based high side power supply
download

Explorar videos