TIPD135
10uA-100mA, 0.05% 오류, 고압측 전류 감지 솔루션 레퍼런스 디자인
TIPD135
개요
This precision verified design provides the theory, component selection, simulation, complete PCB schematic and layout, bill of materials, and measured performance of a split-supply, high-side four decade current sensing solution that can accurately detect load currents from 10uA-100mA. The corresponding linear output is from 10mV to 4.9V which enables measurement by common 5V ADCs. The design utilizes the PGA281, an instrumentation amplifier with pin-programmable gain and a wide common-mode voltage range, to provide a more accurate and versatile solution than traditional op amps.
특징
- High-Side, Four Decade, Bi-directional, Current Sensing Verified Solution
- Senses Current from 10uA-100mA with <0.05% Error
- Supports up to ±12.5V Common-mode Input Range
- 10mV to 4.9V output for measurement by common 5V ADCs
- Utilizes PGA281 pin-programmable gain instrumentation amplifier to achieve four decade current measurement
This Verified Design Includes:
- Theory
- Component Selection
- TINA-TI Simulation
- Schematics and PCB Layout
- Verification and Measured Performance
- Modification Options
완조립 보드는 테스팅과 성능 검증을 위해서만 개발되었으며 판매를 위한 것이 아닙니다.
설계 파일 및 제품
설계 파일
바로 사용 가능한 시스템 파일을 다운로드하여 설계 프로세스에 속도를 높여 보십시오.
개발 시작하기
지원 소프트웨어
The design resource accessed as www.ti.com/lit/zip/tidc002 or www.ti.com/lit/xx/tidc002/tidc002.zip has been migrated to a new user experience at www.ti.com/tool/download/TIDC002. Please update any bookmarks accordingly.
지원 소프트웨어
The design resource accessed as www.ti.com/lit/zip/tidc003 or www.ti.com/lit/xx/tidc003/tidc003.zip has been migrated to a new user experience at www.ti.com/tool/download/TIDC003. Please update any bookmarks accordingly.
기술 자료
검색된 결과가 없습니다. 검색어를 지우고 다시 시도하세요.
1개 모두 보기
| 유형 | 직함 | 최신 영어 버전 다운로드 | 날짜 | ||
|---|---|---|---|---|---|
| 사용 설명서 | 10-uA to 100-mA 0.05%-Error High-Side Current Sensing Design Guide | 2013. 10. 3 |