Inverting op amp with non-inverting positive reference voltage circuit

00:04:16 | 30 DEC 2022
This design uses an inverting amplifier with a non-inverting positive reference voltage to translate an input signal of –1 V to 2 V to an output voltage of 0.05 V to 4.95 V. This circuit can be used to translate a sensor output voltage with a positive slope and negative offset to a usable ADC input voltage range.

Resources

  • downloadPresentation
  • arrow-right Order samples and learn more about the op amp used in this video
  • arrow-right View our portfolio of operational amplifiers
  • arrow-right Evaluate and prototype with amplifiers using TI’s DIYAMP-EVM
  • arrow-right Learn more about the circuit from this video