VIDEO SERIES

Troubleshooting tips: op amps

This training highlights various techniques to assist with application problem-solving, debugging and datasheet measurements on our op amps.

Troubleshooting Tips: Op Amps - Offset Voltage

In this training we demonstrate how to verify the input offset voltage of an amplifier using the TI product datasheet test conditions.

00:04:30|30 May 2019

Understanding how to verify datasheet specifications such as input voltage offset is critical to the application troubleshooting and debugging process. In this training the false summing junction circuit is utilized to demonstrate how to determine the input offset voltage of a linear amplifier. At the system level an offset voltage anomaly may result in the following signatures:

  • Increased or decreased output voltage compared to the nominal

  • Anomalous reading observed by ADC

  • Unexpected sensor reading