This TI Precision Labs - Op Amps Series training video discusses op amp input and output limitations, part 2. In this video, we’ll discuss the details of several factors inside an amplifier which cause common-mode, or input voltage range, limitations, as well as the advantages and disadvantages of different op amp input topologies.