JAJSKT4J July   2021  – November 2023 BQ77216

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. 概要 (続き)
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 DC Characteristics
    6. 7.6 Timing Requirements
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Voltage Fault Detection
      2. 8.3.2 Open-Wire Fault Detection
      3. 8.3.3 Temperature Fault Detection
      4. 8.3.4 Oscillator Health Check
      5. 8.3.5 Sense Positive Input for Vx
      6. 8.3.6 Output Drive, COUT and DOUT
      7. 8.3.7 The LATCH Function
      8. 8.3.8 Supply Input, VDD
    4. 8.4 Device Functional Modes
      1. 8.4.1 NORMAL Mode
      2. 8.4.2 FAULT Mode
      3. 8.4.3 Customer Test Mode
  10. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Design Requirements
      2. 9.1.2 Detailed Design Procedure
        1. 9.1.2.1 Cell Connection Sequence
    2. 9.2 Systems Example
  11. 10Power Supply Recommendations
  12. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  13. 12Device and Documentation Support
    1. 12.1 サード・パーティ製品に関する免責事項
    2. 12.2 ドキュメントの更新通知を受け取る方法
    3. 12.3 サポート・リソース
    4. 12.4 Trademarks
    5. 12.5 静電気放電に関する注意事項
    6. 12.6 用語集
  14. 13Revision History
  15. 14Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MIN MAX UNIT
Supply voltage range VDD – VSS –0.3 85 V
Input voltage range Vn – VSS where n = 1 to 16 –0.3 85 V
TS –0.3 1.5 V
Output voltage range COUT – VSS, DOUT – VSS –0.3 85 V
Functional temperature, TFUNC –40 110 °C
Storage temperature, TSTG –65 150 °C
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.