JAJSOF8I February   1994  – October 2022 SN55LBC180 , SN65LBC180 , SN75LBC180

PRODUCTION DATA  

  1. 特長
  2. 概要
  3. 概要 (続き)
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 Dissipation Rating Table
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information Table
    5. 6.5 Driver Section
      1. 6.5.1 Electrical Characteristics
      2. 6.5.2 Switching Characteristics
      3. 6.5.3 Switching Characteristics: SN55LBC180
    6. 6.6 Receiver Section
      1. 6.6.1 Electrical Characteristics
      2. 6.6.2 Switching Characteristics
      3. 6.6.3 Switching Characteristics: SN55LBC180
    7. 6.7 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Function Tables
    2. 8.2 Schematics of Inputs and Outputs
  9. Application and Implementation
    1. 9.1 Application Information
  10. 10Device and Documentation Support
    1. 10.1 Receiving Notification of Documentation Updates
    2. 10.2 サポート・リソース
    3. 10.3 商標
    4. 10.4 Electrostatic Discharge Caution
    5. 10.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • D|14
  • RSA|16
  • N|14
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

See note (1)
UNIT
VCCSupply voltage range (2)–0.3 to 7V
VBUSBus voltage range (A, B, Y, Z)(2)–10 to 15V
Voltage range at D, R, DE, RE(2)–0.3 to VCC + 0.5V
Continuous total power dissipation(3)Internally limited
Total power dissipationSee Dissipation Rating Table
TstgStorage temperature range–65 to 150°C
IOReceiver output current range–50 to 50mA
ESDElectrostatic dischargeHBM (Human Body Model) EIA/JESD22-A114±4kV
MM (Machine Model) EIA/JESD22-A115400V
CDM (Charge Device Model) EIA/JESD22-C1011.5kV
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to GND.
The maximum operating junction temperature is internally limited. Use the dissipation rating table to operate below this temperature.