JAJSR77 September 2023 UCC21738-Q1
PRODUCTION DATA
OC protection is used to sense the current of the SiC-MOSFETs and IGBTs under overcurrent or shoot-through condition. Figure 7-10 shows the timing diagram of OC operation with soft turn-off.